C122
In the parameters of the batch commands
is an error!
e.g.
ProductCode = 0
letterId = 0
A parameter transferred in the batch commands from external devices (e.g. GKBK-PC, semi-dynamic
scale) was invalid. => Change software of the external devices.
C123
Error with external scales. Please note the
display on the scales.
remedy see display dyn. scale
Please verify the cable between dyn. scale and franking machine.
C124
Error protocol version of the scale.
The software version (protokoll) of the scale does not correspond with the ultimail.
Remedy:
Verify software releases of franking machine and external scale.
C150
Internal error: Accounting service cannot
be opened.
Security Modue not plugged / defective / sequence error H103
=>E: 1)plug SD correct check or 2) exchange adapter board in SD housing
3) exchange mainboard
Info:
Error C150 is only possible if the PSD is in the state valid.
The accounting service becomes open before the letter transport starts, to make sure everything is
ready (pieces- date credit money availeble...). C150 is a message byside of C109 and E113
Check the connection between main board, adapter board (in the PSD housing) and PSD
C151
No credit loaded to security module.
No money loaded / Security Module not plugged / defective
=>C: run TELESET
C152
No credit in this account.
=> C: run TELESET
C154
Internal error: Print image could not be
created!
Probably sequence error
=>C: clear error message, if necessary restart FM
C155
No account selected: Please insert an
access card.
Eventually a contact problem
=> C: check chip card, insert chip card with chip to the bottom, insert chip card beyond the pressure
point
diagnostic-
code
subcode1
subcode2
diagnostic message remedy
ISS international service support
page 9 Ultimail