
E127 xxx2 xxxx
xxxx xxxx
left cartridge => HP-ASIC to hot (<142°C)
machine is blocked
=> C: exchange cartridge, install again
=> T: run contact test in Service mode, exchange the pen driver board (RDS mover)
E127 xxx4 xxxx
xxxx xxxx
left cartridge => calibration failed
=> C: exchange cartridge, install again
=> T: run contact test in Service mode, check the temperature on the cartridge Service mode->
cartridge info. If the temp is 0°C please exchange the splitter board and/or (RDS mover) .
see tecchnical bulletin #1
E127 xxx8 xxxx
xxxx xxxx
left cartridge => print voltage to low => C: exchange cartridge, install again
=> T: run contact test in Service mode, check temperatur on the cartridge in service mode => cartridge
info
search for your subcode…
see also technical bulletin #1
E127 xxxx xx1x
xxxx xxxx
right cartridge => print voltage to high
=> C: exchange cartridge, install again
=> T: run contact test in Service mode, check temperatur on the cartridge in service mode => cartridge
info
see also technical bulletin #1
E127 xxxx xx2x
xxxx xxxx
right cartridge => low voltage
=> C: exchange cartridge, install again
=> T: run contact test in Service mode, exchange the pen driver board (RDS mover)
E127 xxxx xx4x
xxxx xxxx
left cartridge => contact problem Cotact problem /Cartridge failer
=> C: exchange cartridge, install again
=> T: run contact test in Service mode
search for your subcode…
see also technical bulletin #1
E127 xxxx xx8x
xxxx xxxx
right cartridge => identification error
=>C: install cartridge again, exchange the cartridge
maybe wrong or non FP cartridge?
=>T: run contact test in service mode and clean the contacts
E127 xxxx xxx1
xxxx xxxx
right cartridge => HP-ASIC to warm
(>125C)
=> C: exchange cartridge, install again
=> T: run contact test in Service mode, exchange the pen driver board (RDS mover)
diagnostic-
code
subcode1
subcode2
diagnostic message remedy
ISS international service support
page 16 Ultimail
Comentários a estes Manuais