C100
Process initialization failed.
root causes will be highlighted at subsequent diagnosis codes
C101
Insufficient credit loaded to security
module.
No money loaded / Security Module not plugged
=> C: download postage
=> T: plug SM
C102
No credit in this account.
=> C: assign credit to appropriate account
C103 0000 0000
xxxx xxxx
Invalid SD status.
state is UNDDEFINED
SD is not right connected/defect
if the step from autorized to valid is not running-> expand the piece credit
the registration by the postal authority is required
=> T: connect the SD, check the state
exchange the SD Adapter board
C103 0000 0001
xxxx xxxx
invalid SD state
State is MANUFACTURED
SD is connected but invalid state
exchange the SD
the registration by the postal authority is required
C103 0000 0002
xxxx xxxx
invalid SD state
State is NEW
There is the very first initializing (OMI1) in the factory missing
send the machine back to FP
C103 0000 0003
xxxx xxxx
invalid SD state
state is INITIALIZED
Not a Error!
Installation must be completed
C103 0000 0004
xxxx xxxx
invalid SD state
state is AUTHORIZED
C: Run Teleset
C: Send the remote data, check the date- and pieces credit and the HS-Loop state
If the date/pieces credit is low and get not refreshed by a reset, please contact TDC/FPI Admin.
If the HS-Loop is open then a technican is required
C103 0000 0005
xxxx xxxx
SD state is VALID
can normally not be happen, because the machine is valid
diagnostic-
code
subcode1
subcode2
diagnostic message remedy
ISS international service support
email: [email protected] created : 20.11.2007 19:33 Uhr