C108
No communication with security module Security Module not plugged / defective
should be done by technicain:
1) run SD echo test and SD selftest in Service mode
check/plug/connect SM correctly again
Since Jan/04 the SD/main board connection get modificated. A bad connection is improbably.
C109
Cannot perform franking: last postage rate
loading too long ago! Please perform
TELESET. Amount 0 is sufficient.
Subcode 2: 0000 0001 Datecredit expired,
=> C: run TELESET with '0‘
=> C: T: check system info -> pieces and date credit, maybe contact the TDC-Team to set a new credit
C109 xxxx xxxx
0000 0001
Cannot perform franking: last postage rate
loading too long ago! Please perform
TELESET. Amount 0 is sufficient.
Date credit is expired
=> C: run teleset 0 is enough
=> C: T: check system info -> pieces and date credit, maybe contact the TDC-Team to set a new credit
C109 xxxx xxxx
0001 0000
Cannot perform franking: last postage rate
loading too long ago! Please perform
TELESET. Amount 0 is sufficient.
=> C: run teleset 0 is enough
C110
Please perform TELESET first.
Warning before C109
Advance warning for C109
=> C: run TELESET with '0‘
C111
Service interval reached! Please contact
FP service dept.
=> C: clear error message, call customer service for maintenance
C112
The descending register (R1) is below the
set warning threshold! Please perform
TELESET in good time.
=> C: run TELESET
C113
Memory battery B is almost flat, please
replace it immediately!
=> C: replace battery, only use original FP battery
diagnostic-
code
subcode1
subcode2
diagnostic message remedy
ISS international service support
page 7 Ultimail