D116
Security module communication error
Security device is not plugged in the right way or is defect.
Remedy:
Verify position of security device and perform selftest to check functionality.
E100
Unable to position (reference) print
cartridge direction.
Green catches at Inkjet cartridges are not latched / cartridge flap open
=> C: check green catches (start menu 'change ink cartridges' but abort after check), close cartridge
flap
=> T: 1) Enter service mode->motortest -> make refernce test several times. If the reference change
more than 5, please check RDS mover mechanic, is the set screw open (not tide)? (see service
manual Chap.3 page.8
2) run Sensortest may be the position sensors are defect!
E102
The control data for the pen carrier is
invalid.
Sequence error =>
E106
Incorrect command for setting the
parameters for the pen carrier.
=> T: check the RDS mover drive
check fuse on the main board
exchange mainboard
E108
Incorrect command for starting the pen
mover during sensor test.
Green catches at Inkjet cartridges are not latched / cartridge flap open
=>C: check green catches (start menu 'change ink cartridges' but abort after check), close cartridge
flap
T: 1) Connector between upper housing and lower unit is not connected?
2) Cartridge micro switch is defect/ not actuated?
3) during main board exchange is the big flat ribbon cable not connected/defect?
E109
Incorrect speed set for letter transport.
Feeder connected to ultimail 60 or sealer connected to ultimail 90 => SW didn't allow to use this