H116
In Canada muss die CreationTime
innerhalb eines Batches (zwischen zwei
PVDs) aufsteigend sein. Dies ist hier nicht
der Fall. Hinweis für Benutzer
Zeitzone umgestellt,
Umschaltung von Sommer- auf Winterzeit => PVD durchführen
H117
illeagal SD change illeagal SD change at LMR-variant ((LRM - LocalResetingMachine)
SD-ID of new SD is unknown and registers r1 - r4 are not zero.
remedy:
Delete pin ta servicemode ( 1930-DELETE LRM-PIN)
I150
Insufficient access authorizations (card
level)
=> Please use chip card with higher access rights (Dealer-, FP-, Factory card)
I152
Unable to create more accounts ...
=> are the max number of cost account already in use? In the ultimail60 is it possible to by a code
which expand the number of 10 accounts to 50.
L100
Chip card read error!
Chip card was inserted the wrong way round
=>C: check chip card, insert chip card with chip to the bottom, insert chip card beyond the pressure
point
M039
like G039
It's a German BZL feature -> no more
serial no. available
Run teleset
M100
Unspecified error during postage
calculation, returned by postage table
=> C:T: load rate tabel again
M101
Postage table returning Entry not found
error
=> select other product, load new rate table
M102
Postage table returning “Weight range
exceeded” error
=>C: Please install a new valid rate table, depending the country version, load it via chip card or
remote via modem.
diagnostic-
code
subcode1
subcode2
diagnostic message remedy
ISS international service support
page 31 Ultimail
Comentários a estes Manuais