RDS A100 Manual de Serviço Página 31

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 42
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 30
H116
In Canada muss die CreationTime
innerhalb eines Batches (zwischen zwei
PVDs) aufsteigend sein. Dies ist hier nicht
der Fall. Hinweis für Benutzer
Zeitzone umgestellt,
Umschaltung von Sommer- auf Winterzeit => PVD durchführen
H117
illeagal SD change illeagal SD change at LMR-variant ((LRM - LocalResetingMachine)
SD-ID of new SD is unknown and registers r1 - r4 are not zero.
remedy:
Delete pin ta servicemode ( 1930-DELETE LRM-PIN)
I150
Insufficient access authorizations (card
level)
=> Please use chip card with higher access rights (Dealer-, FP-, Factory card)
I152
Unable to create more accounts ...
=> are the max number of cost account already in use? In the ultimail60 is it possible to by a code
which expand the number of 10 accounts to 50.
L100
Chip card read error!
Chip card was inserted the wrong way round
=>C: check chip card, insert chip card with chip to the bottom, insert chip card beyond the pressure
point
M039
like G039
It's a German BZL feature -> no more
serial no. available
Run teleset
M100
Unspecified error during postage
calculation, returned by postage table
=> C:T: load rate tabel again
M101
Postage table returning Entry not found
error
=> select other product, load new rate table
M102
Postage table returning “Weight range
exceeded” error
=>C: Please install a new valid rate table, depending the country version, load it via chip card or
remote via modem.
diagnostic-
code
subcode1
subcode2
diagnostic message remedy