RDS A100 Manual de Serviço Página 6

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 42
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 5
C104 xxxx xxxx
0000 0005
machine is not ready
the autorization failed
repeat autorization
C104 xxxx xxxx
0000 0006
machine is not ready
the accounting process failed
start meter again and try again.
C104 xxxx xxxx
0000 0007
printing impossible
State: ErrNoMoneyInSD => No money
availeble in the SD
run teleset, load money
C104 xxxx xxxx
0000 0008
machine is not ready
no money for this account
change cost account
run teleset
C105
Cannot perform franking.
Inkjet cartridges not inserted / cartridges not correct calibrated / RDS not in correct position
if subcode 1=000000B, than incorrect cliche data are possible => C: insert inkjet catridges / C: check
that green catches lock both cartridges correct / C: calibrate cartridges (remove cartridges and insert
them again)
C105 0000 000B
xxxx xxxx
Metering and weighing impossible => may
missing/incorrect print image data
Install new print image data
=>C: Check Mem 1 settings, Mem 1 is the power up reference, please program correct settings which
make sence.
=>C: Check if there is a rate table present. Send remote diagostic data.
If there is SW <03.11.00 in use error C105 appears (also PCE countrys). Since 03.11.00 you get error
M145 if a rate table is missing.
=>C: Run a cartridge calibration again by simulate a cartridge exchange (use the old cartridges again)
C106
The machine cannot be switched off.
=> C: wait a while, unplug mains plug
C107
NVRAM RECALL performed
This diagnosis code is not used.
diagnostic-
code
subcode1
subcode2
diagnostic message remedy
ISS international service support
email: [email protected] created : 20.11.2007 19:33 Uhr
page 6 Ultimail
Vista de página 5