E147
temperature of print cartridges to high
Unacceptable temperature of print cartridges (> 55°C) is detected. Print quality will be effected.
Subcode 1 show temperature of cartridge 1 at Pen 1 [in deg]
Subcode 2 show temperature of cartridge 0 at Pen 0 [in deg]
This error can be reported during longer print pauses.
It may be caused by:
- wrong working temperature sensor at splitter board
- wrong temperature calibration of cartridges. e.g. if a cold cartridge was inserted in a warm machine.
Please perform change cartridge without changing chartidges - temperature calibration of cartridges is
performed again.
- If cartridge is empty also high temperatures are caused.
- During the print head startup test, faulty resistors on the cartridge becomes also reported as error
E148
The encoder data for the letter transport
drive is faulty.
Subcode 1: Number of encoder defects
=>T: check, clean, change encoder.
Check encoder cable (shifted imprint?)
E149
The feeder is not switched on
power cord of the feeder unit is not connected
=>C: check the power cord
E150
The sealer is not switched on
=> C: check connecting cable
E151
Label incorrectly positioned in machine C: check labels, eliminate label jam (draw label dispenser, unlock letter transport (please refer to
section removing letter jams of ultimail operator manual))
Use FP Label only!
=>T: sw update 03.01.02 and higher more details see TI 17a
E152
No more letters are in the feeder for list
print so the list print is aborted.
=> C: insert more envelopes and repeat list printing