E140
Unable to transfer data to print cartridges.
1: Print cartridge status information, as
under E127
2: Consumable protection status
information, as under E127
Contact problems / ink cartridge error / swapped cartridges
=>C: insert Inkjet cartridges again, replace ink cartridges
=>T: check contact properties in service mode
bad CP-Chip aplikation, PBD clean, check, exchange
E141
Unable to detect label properly. =>C: check labels, eliminate label jam (remove label dispenser subject, unlock letter transport (please
refer to section removing letter jams of ultimail operator manual))
Use FP Label only!
=>T: sw update 03.01.02 and higher more details TI 17a. Because the lable handling becomes
modified.
E142
Unable to calibrate label dispenser
sensor.
Sensor could not be calibrated - a label covers it =>
=>C: if necessary remove label from label passage, switch ultimail off and on again
E143
Unable to read data from print cartridges.
Contact problems / ink cartridge error / swapped cartridges
=> C: insert Inkjet cartridges again, replace ink cartridges
=> T: SW update min.: 02.39.07
E144
Print voltage has fallen to an
unacceptable value.
Polyswitch has triggered. Short circuit or to high current load to the or on the PenDriverBoard
=>T: Check PDB, PDB cable, and mainboard
E146
Errors occurred during printing process.
Subcode 1:cartridge-statusinformation
subcode
Contact problems / ink cartridge error / swapped cartridges
=> C: insert Inkjet cartridges again, replace ink cartridges
=> T: PDB's check, clean, change
run contact test in service mode
print voltage to low/high it is not s cartridge problem
see E146
diagnostic-
code
subcode1
subcode2
diagnostic message remedy
ISS international service support
page 21 Ultimail