C156
Internal error: Letter started but not
completed.
=> C: insert letter again
C157
Internal error: Process steps not
recognized.
=>C: switch FM off/on again
C158
Internal error: READY_flags not present!
=> C: run TELESET with '0'
C159
Ink cartridges misaligned.
Ink cartridges are missing / are defective / not contacted, cartridges were removed and then swapped
=> C: perform a cartridge change with used cartridges, if all nothing helps insert new cartridges
C160
valid imprints are possible only, if the PC
(Karat) signal is present.
Please check the Karat state.
=> Please switch the KARAT (PC-System) into the ready mode
C161
Print system is not ready! Please return to READY mode by using
Setup => select mode => franking => standard franking
or
press C/CE minimum 3 seconds
please check previous diagnosis codes, may be a inherited error
e.g.: Cartridge are not detected. Info out of the field: SW update >2.39.xx solve this Problem.
C305
Security task start up failed due to error.
Security Module not plugged / defective
=> E: plug Security Module again,
change adapter board (in the PSD housing),
change main board
C307
Keyboard task start up failed due to error.
=> T: run keyboard test, check cabel
diagnostic-